Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Eur J Radiol ; 154: 110453, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35926356

RESUMO

OBJECTIVE: To investigate if the presence of metallic markers (markers) influences the diagnostic accuracy of preoperative breast MRI for the prediction of pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) in breast cancer patients. MATERIALS AND METHODS: In this single-center, retrospective, observational study approved by the IRB of our institution, we included all consecutive patients that underwent preoperative breast MRI after completion of NAC (Mean 4,4 days ± 15,9). The presence or absence of markers, the type of markers, the size and type of artefact on each MRI sequence were recorded. Two radiologists blinded to histopathological results and to each other's findings evaluated all MRI examinations for presence or absence of complete response. Pathology was the standard of reference. Diagnostic performance of MRI for prediction of pCR in the presence or absence of markers and also between two most represented markers brands (O'Twist and UltraClip) were compared using Chi-squared tests or equivalents. RESULTS: Ninety-three patients (mean age 48 ± 11 years) were included in this study. Nineteen of them had no markers and 74 had 108 markers. Sensitivity and specificity of MRI for the prediction of pCR were 0.73 and 0,81 for patients with and 0.67 and 0.90 for patients without markers (p < 0.05).There was no statistical difference in the performance of MRI for the two different types of markers studied. CONCLUSION: Diagnostic performance of pre-operative MRI after NAC for the prediction of pCR did not differ statistically in the presence or absence of metallic markers nor between the two markers' brands studied.


Assuntos
Neoplasias da Mama , Mama , Adulto , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Terapia Neoadjuvante/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
2.
Brain Behav ; 12(1): e2449, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34862855

RESUMO

BACKGROUND: Synthetic MRI (SyMRI) is a quantitative technique that allows measurements of T1 and T2 relaxation times (RTs). Brain RT evolution across lifespan is well described for the younger population. The aim was to study RTs of brain parenchyma in a healthy geriatric population in order to define the normal value of structures in this group population. Normal values for geriatric population could help find biomarker for age-related brain disease. MATERIALS AND METHODS: Fifty-four normal-functioning individuals (22 females, 32 males) with mean age of 83 years (range 56-98) underwent SyMRI. RT values in manually defined ROIs (centrum semiovale, middle cerebellar peduncles, thalamus, and insular cortex) and in segmented whole-brain components (brain parenchyma, gray matter, white matter, myelin, CSF, and stromal structures) were extracted from the SyMRI segmentation software. Patients' results were combined into the group age. Main ROI-based and whole-brain results were compared for the all dataset and for age group results as well. RESULTS: For white matter, RTs between ROI-based analyses and whole-brain results for T2 and for T1 were statistically different and a trend of increasing T1 in centrum semiovale and cerebellar peduncle was observed. For gray matter, thalamic T1 was statistically different from insular T1. A difference was also found between left and right insula (p < .0001). T1 RTs of ROI-based and whole-brain-based analyses were statistically different (p < .0001). No significant difference in T1 and T2 was found between age groups on ROI-based analysis, but T1 in centrum semiovale and thalamus increased with age. No statistical difference between age groups was found for the various segmented volumes except for myelin between 65-74 years of age and the 95-105 years of age groups (p = .038). CONCLUSIONS: SyMRI is a new tool that allows faster imaging and permits to obtain quantitative T1 and T2. By defining RT values of different brain components of normal-functioning elderly individuals, this technique may be used as a biomarker for clinical disorders like dementia.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Feminino , Substância Cinzenta/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Bainha de Mielina , Substância Branca/diagnóstico por imagem
3.
Skeletal Radiol ; 50(1): 231-237, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32761256

RESUMO

OBJECTIVE: To evaluate the value of synthetic magnetic resonance imaging (MRI) and T2 mapping in distinguishing between different types of fillers in soft tissues. MATERIALS AND METHODS: Ex vivo fillers of buttock soft tissues (silicone, collagen, and different types of hyaluronic acid) were scanned using a synthetic MRI sequence at 1.5 and 3 T and an optimized T2 mapping sequence to measure the T2 relaxation times of the fillers ex vivo. Three patients addressed to assess complications with buttock fillers underwent MRI with the standard morphological sequences and an additional synthetic MRI sequence; T2 mapping was not performed for the patients. Two patients had silicone fillers, whereas the exact filler composition for the third patient was unknown. RESULTS: Measurements of T1 and T2 relaxation times of ex vivo fillers at 1.5 and 3 T using synthetic MRI showed that the silicone, collagen, and hyaluronic acid had distinct relaxation time characteristics. In vivo, the synthetic MRI correctly identified silicone in the two patients with known silicone fillers, showing low T1 and T2 values, whereas in the third patient with an unknown filler type, the synthetic MRI suggested a collagen filler, with intermediate relaxation time values. CONCLUSION: Quantitative sequences have the potential to differentiate between filler types in a noninvasive fashion.


Assuntos
Imageamento por Ressonância Magnética , Procedimentos de Cirurgia Plástica , Humanos , Ácido Hialurônico , Espectroscopia de Ressonância Magnética , Próteses e Implantes
4.
Knee Surg Sports Traumatol Arthrosc ; 28(2): 353-362, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31209539

RESUMO

PURPOSE: To assess knee health in retired female football players, using magnetic resonance imaging (MRI) and self-report. The focus of analysis were degenerative changes of the tibiofemoral joint, and their relationship to osteoarthritis symptoms and previous knee injury. METHODS: Forty-nine retired elite, female football players (98 knees) aged 37 years on average participated. Tibiofemoral cartilage and meniscus status of both knees were evaluated using MRI and graded according to modified Outerbridge and Stoller classifications, respectively. Symptoms were assessed through a standardised questionnaire (Knee Osteoarthritis Outcome Score: KOOS). Knee injury history was recorded via a semi-structured interview. To investigate how injury variables relate to outcomes, binary logistic regression models were used and reported with odds ratios (OR). RESULTS: Fifty-one per cent of players (n = 25) fulfilled the MRI criterion for knee osteoarthritis, 69.4% (n = 34) had substantial meniscal loss and 59.6% (n = 28) reported substantial clinical symptoms. Chondral- and meniscal loss were associated with significantly lower scores on three of five KOOS subscales (p < .05). Both chondral and meniscal loss were significantly predicted by previous traumatic knee injury (OR = 4.6, OR = 2.6), the injury affecting the non-striking leg (OR = 8.6, OR = 10.6) and type of injury; participants with combined ACL/meniscus injuries had the highest risk for substantial chondral and meniscal loss (OR = 14.8, OR = 9.5). Chondral loss was significantly predicted by isolated meniscus injury treated with partial meniscectomy (OR = 5.4), but not by isolated reconstructed ACL injury. Clinical symptoms were only significantly predicted by previous traumatic knee injury (OR = 5.1). CONCLUSIONS: Serious degenerative changes were found in a high number of retired female football players' knees 10 years after their career. Meniscal integrity is key for knee osteoarthritis outcomes in young adults, and thus, its preservation should be a priority.


Assuntos
Osteoartrite do Joelho/diagnóstico por imagem , Futebol/lesões , Adulto , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Estudos Transversais , Feminino , Humanos , Traumatismos do Joelho/complicações , Traumatismos do Joelho/cirurgia , Imageamento por Ressonância Magnética , Masculino , Meniscectomia , Menisco/diagnóstico por imagem , Pessoa de Meia-Idade , Autorrelato , Lesões do Menisco Tibial/complicações , Lesões do Menisco Tibial/cirurgia
5.
Magn Reson Med ; 81(1): 560-572, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29893989

RESUMO

PURPOSE: The morphological and hemodynamic evaluations of neurovascular diseases treated with stents would benefit from noninvasive imaging techniques such as 3D time-of-flight MRI (3D-TOF) and 3D phase contrast MRI (3D-PCMRI). For this purpose, a comprehensive evaluation of the stent artifacts and their impact on the flow measurement is critical. METHODS: The artifacts of a representative sample of neurovascular stents were evaluated in vitro with 3D-TOF and 3D-PCMRI sequences. The dependency of the artifacts with respect to the orientation was analyzed for each stent design as well as the impact on the flow measurement accuracy. Furthermore, the 3D-PCMRI data of four patients carrying intracranial aneurysms treated with flow diverter stents were analyzed as illustrative examples. RESULTS: The stent artifacts were mainly confined to the stent lumen therefore indicating the leading role of shielding effect. The influence of the stent design and its orientation with respect to the transmitting MR coils were highlighted. The artifacts impacted the 3D-PCMRI velocities mainly in the low magnitude domains, which were discarded from the analysis ensuring reliable near-stent velocities. The feasibility of in-stent flow measurements was confirmed in vivo on two patients who showed strong correlation between flow and geometric features. In two other patients, the consistency of out-of-stent velocities was verified qualitatively through intra-aneurysmal streamlines except when susceptibility artifacts occurred. CONCLUSION: The present results motivate the conception of low inductance or nonconductive stent design. Furthermore, the feasibility of near-stent 3D-PCMRI measurements opens the door to clinical applications like the post-treatment follow-up of stenoses or intracranial aneurysms.


Assuntos
Aneurisma/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Neurônios/metabolismo , Stents , Algoritmos , Artefatos , Velocidade do Fluxo Sanguíneo , Vasos Sanguíneos/metabolismo , Circulação Cerebrovascular , Cromo/química , Cobalto/química , Hemodinâmica , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Teste de Materiais , Níquel/química , Reprodutibilidade dos Testes , Titânio/química , Procedimentos Cirúrgicos Vasculares/efeitos adversos
6.
Eur Radiol ; 28(2): 651-663, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28812148

RESUMO

PURPOSE: To determine the diagnostic performance of FDG-PET/MRI with diffusion-weighted imaging (FDG-PET/DWIMRI) for detection and local staging of head and neck squamous cell carcinoma (HNSCC) after radio(chemo)therapy. MATERIALS AND METHODS: This was a prospective study that included 74 consecutive patients with previous radio(chemo)therapy for HNSCC and in whom tumour recurrence or radiation-induced complications were suspected clinically. The patients underwent hybrid PET/MRI examinations with morphological MRI, DWI and FDG-PET. Experienced readers blinded to clinical/histopathological data evaluated images according to established diagnostic criteria taking into account the complementarity of multiparametric information. The standard of reference was histopathology with whole-organ sections and follow-up ≥24 months. Statistical analysis considered data clustering. RESULTS: The proof of diagnosis was histology in 46/74 (62.2%) patients and follow-up (mean ± SD = 34 ± 8 months) in 28/74 (37.8%). Thirty-eight patients had 43 HNSCCs and 46 patients (10 with and 36 without tumours) had 62 benign lesions/complications. Sensitivity, specificity, and positive and negative predictive value of PET/DWIMRI were 97.4%, 91.7%, 92.5% and 97.1% per patient, and 93.0%, 93.5%, 90.9%, and 95.1% per lesion, respectively. Agreement between imaging-based and pathological T-stage was excellent (kappa = 0.84, p < 0.001). CONCLUSION: FDG-PET/DWIMRI yields excellent results for detection and T-classification of HNSCC after radio(chemo)therapy. KEY POINTS: • FDG-PET/DWIMRI yields excellent results for the detection of post-radio(chemo)therapy HNSCC recurrence. • Prospective one-centre study showed excellent agreement between imaging-based and pathological T-stage. • 97.5% of positive concordant MRI, DWI and FDG-PET results correspond to recurrence. • 87% of discordant MRI, DWI and FDG-PET results correspond to benign lesions. • Multiparametric FDG-PET/DWIMRI facilitates planning of salvage surgery in the irradiated neck.


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Fluordesoxiglucose F18/farmacologia , Neoplasias de Cabeça e Pescoço/diagnóstico , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Feminino , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Carcinoma de Células Escamosas de Cabeça e Pescoço
7.
Magn Reson Med ; 79(1): 129-140, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28244132

RESUMO

PURPOSE: Recent advances in 3D-PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non-negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D-PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments. METHODS: The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D- and 3D-PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D- and 3D-PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging. RESULTS: The in vitro 2D- and 3D-PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D-PCMRI flow rates measured in vivo in ICA agreed very well with 2D-PCMRI data and a good flow conservation was observed at the C7 bifurcation. Globally, partial volume correction led to 10-15% lower flow rates than uncorrected values as those reported in most of the published studies on intracranial flows. CONCLUSION: Partial volume correction may improve the accuracy of PCMRI flow rate measurements especially in small vessels such as intracranial arteries. Magn Reson Med 79:129-140, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Artéria Carótida Interna/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Velocidade do Fluxo Sanguíneo , Artérias Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular , Feminino , Hemodinâmica , Humanos , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Fluxo Pulsátil
8.
Radiol Med ; 122(10): 731-742, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28643295

RESUMO

OBJECTIVE: To compare two fat suppression techniques used for 3D T1-weighted sequence in breast MRI (magnetic resonance imaging), namely Dixon versus spectral fat saturation (fat sat). MATERIALS AND METHODS: All breast MRI examinations performed in a Philips 3 T unit between March 2013 and October 2015 including either a Dixon or a fat sat sequence were retrospectively analyzed. The examinations were subjectively evaluated by two independent experienced readers in a scale of 5 for overall quality of fat suppression, homogeneity of fat suppression, definition of anatomic structures and focal lesions, diagnostic confidence for axillary and internal mammary regions and the presence of artifacts, 1 corresponding to excellent and 5 to non-diagnostic quality. Contrast-to-noise-ratio (CNR) measurements for muscle and focal lesions were also performed. RESULTS: Overall 161 women (mean age 51.6 ± 12.0 years) underwent 189 MR examinations, 113 with the fat saturation and 76 with the Dixon sequence. Interobserver variability was good (kappa = 0.757). In all subjectively evaluated parameters, the Dixon sequence was superior to the fat sat (p < 0.05). Mean values of CNR for muscle and focal lesions were 9.98 (±4.2), 17.9 (±7.53) for the fat sat and 18.3 (±10.4) and 29.3 (±14.1) for the Dixon sequence, respectively (p < 0.001). CONCLUSION: 3D T1 Dixon sequence is superior to fat sat for dedicated breast MRI at 3 T, in terms of efficiency of fat suppression and image quality with the added advantage of optimal exploration of the axillary areas.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Curr Alzheimer Res ; 14(2): 186-197, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27334943

RESUMO

PET/MRI tomographs represent the latest development in hybrid molecular imaging, opening new perspectives for clinical and research applications and attracting a large interest among the medical community. This new hybrid modality is expected to play a pivotal role in a number of clinical applications and among these the assessment of neurodegenerative disorders. PET and MRI, acquired separately, are already the imaging biomarkers of choice for a comprehensive assessment of the changes occurring in dementias (major cognitive disorders) as well as in their prodromal phase. In this paper we review the current evidence on the use of integrated PET/MRI scanners to investigate patients with neurodegenerative conditions, and in particular major neurocognitive disorders. The number of studies performed is still limited and shows that the use of PET/MRI gives results overall comparable to PET/CT and MRI acquired independently. We also address the challenges for quantitative aspects in PET/MRI, namely attenuation, partial volume and motion correction and the use of semi-quantitative approaches for FDG PET image analysis in this framework. The recent development of PET tracers for the in vivo differential diagnosis of dementias, able to visualize amyloid and tau deposits, suggests that in the future PET/MRI might represent the investigation of choice for a single session evaluation of morphological, functional and molecular markers.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Transtornos Neurocognitivos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Humanos , Imagem Multimodal , Transtornos Neurocognitivos/metabolismo
10.
J Magn Reson Imaging ; 44(3): 601-9, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26914964

RESUMO

PURPOSE: To assess the influence of perfusion on apparent coefficient diffusion (ADC) maps, the contribution of b-value images, and the number of b-values needed in prostate cancer detection by diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Patients scheduled for prostatectomy were scanned by 3T magnetic resonance imaging (MRI) with DWI based on b-values 0-500-1000-1500 s/mm(2) . A monoexponential model was fitted to obtain ADC using multiple b-values, with or without b0 (perfusion-sensitive ADC4b-b0-500-1000-1500 , perfusion-insensitive ADC3b-b500-1000-1500 ), or two b-values (ADC2b-b0-500 , ADC2b-b0-1000 , ADC2b-b0-1500 ). Prostate and cancer foci were segmented to label voxels as normal or tumoral, according to histology. Areas under receiver operating characteristic curves (AUC) were calculated for each ADC and b-value, then for multivariate logistic regression models combining them. A threshold of 85 tumoral voxels (=0.5 cm(3) ) was used to stratify AUC analysis. RESULTS: In all, 21 patients were selected. Segmentation collected 143,665 prostatic voxels including 10,069 tumoral voxels. In five patients, tumor segmentation provided fewer than 85 voxels, resulting in an ADC with AUC inferior to 0.52. In 16 patients with larger tumors, perfusion-sensitive ADC4b-b0-500-1000-1500 performed better than perfusion-insensitive ADC3b-b500-1000-1500 and similar to ADC2b-b0-1500 (AUC of 0.840, 0.809, and 0.838, respectively). In comparison to the ADC alone, models combining ADC4b-b0-500-1000-1500 or ADC2b-b0-1500 with b1500 improved performance, leading to similar AUCs of 0.884 and 0.883, respectively. In both models, ADC and b1500 were significant markers (P < 0.001). CONCLUSION: Including b0 in ADC calculation provided superior ADC maps for prostate cancer detection. b1500 images as a combined parameter with ADC also improved performance. Using more than two b-values showed no improvement. J. Magn. Reson. Imaging 2016;44:601-609.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Imagem de Difusão por Ressonância Magnética/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Magn Reson Med ; 76(1): 70-82, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26301785

RESUMO

PURPOSE: In this study, we proposed an efficient free-breathing strategy for rapid and improved cardiac diffusion-weighted imaging (DWI) acquisition using a single-shot spin-echo echo planar imaging (SE-EPI) sequence. METHODS: A real-time slice-following technique during free-breathing was combined with a sliding acquisition-window strategy prior Principal Component Analysis temporal Maximum Intensity Projection (PCAtMIP) postprocessing of in-plane co-registered diffusion-weighted images. This methodology was applied to 10 volunteers to quantify the performance of the motion correction technique and the reproducibility of diffusion parameters. RESULTS: The slice-following technique offers a powerful head-foot respiratory motion management solution for SE-EPI cDWI with the advantage of a 100% duty cycle scanning efficiency. The level of co-registration was further improved using nonrigid motion corrections and was evaluated with a co-registration index. Vascular fraction f and the diffusion coefficients D and D* were determined to be 0.122 ± 0.013, 1.41 ± 0.09 × 10(-3) mm(2) /s and 43.6 ± 9.2 × 10(-3) mm(2) /s, respectively. From the multidirectional dataset, the measured mean diffusivity was 1.72 ± 0.09 × 10(-3) mm(2) /s and the fractional anisotropy was 0.36 ± 0.02. CONCLUSION: The slice-following DWI SE-EPI sequence is a promising solution for clinical implementation, offering a robust improved workflow for further evaluation of DWI in cardiology. Magn Reson Med 76:70-82, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Artefatos , Imagem Ecoplanar/métodos , Coração/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Sistemas Computacionais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
12.
Eur Radiol ; 26(7): 2297-307, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26477029

RESUMO

OBJECTIVE: To evaluate the performance of 18F-fluorodeoxyglucose (FDG) positron emission tomography magnetic resonance imaging (PET/MR) for preoperative breast cancer staging. METHODS: Preoperative PET/MR exams of 58 consecutive women with breast cancer were retrospectively reviewed. Histology and mean follow-up of 26 months served as gold standard. Four experienced readers evaluated primary lesions, lymph nodes and distant metastases with contrast-enhanced MRI, qualitative/quantitative PET, and combined PET/MR. ROC curves were calculated for all modalities and their combinations. RESULTS: The study included 101 breast lesions (83 malignant, 18 benign) and 198 lymph node groups, (34 malignant, 164 benign). Two patients had distant metastases. Areas under the curve (AUC) for breast cancer were 0.9558, 0.8347 and 0.8855 with MRI, and with qualitative and quantitative PET/MR, respectively (p = 0.066). Sensitivity for primary cancers with MRI and quantitative PET/MR was 100 % and 77 % (p = 0.004), and for lymph nodes 88 % and 79 % (p = 0.25), respectively. Specificity for MRI and PET/MR for primary cancers was 67 % and 100 % (p = 0.03) and for lymph nodes 98 % and 100 % (p = 0.25). CONCLUSIONS: In breast cancer patients, MRI alone has the highest sensitivity for primary tumours. For nodal metastases, both MRI and PET/MR are highly specific. KEY POINTS: • MRI alone and PET/MR have a similar overall diagnostic performance. • MRI alone has a higher sensitivity than PET/MR for local tumour assessment. • Both MRI and PET/MR have a limited sensitivity for nodal metastases. • Positive lymph nodes on MRI or PET/MR do not require presurgical biopsy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/métodos , Compostos Radiofarmacêuticos , Adulto , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Obes Res Clin Pract ; 9(6): 613-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26052058

RESUMO

OBJECTIVE: The purpose of this study was to assess the performance of (18)F-FDG hybrid PET/MRI to detect and localise the presence of metabolically active brown adipose tissue (BAT). METHODS: We retrospectively analyzed 197 consecutive (18)F-flurodeoxyglucose ((18)F-FDG) positron-emission tomographic (PET) and magnetic resonance imaging (MRI) images performed with a hybrid whole-body PET-MRI tomography in 192 patients. These patients were originally investigated mainly for oncological staging, in the absence of a cooling protocol. The presence of BAT was defined as a soft tissue structure that was larger than 4mm in diameter, had the characteristics of fat tissue on MRI and had a maximal standardised uptake value (SUV) of (18)F-FDG of at least 2.0. No specific MRI sequences for BAT detection were acquired. RESULTS: PET/MRI identified the presence of metabolically active BAT in 5 out of 192 patients (2.6%). BAT positive subjects were all female, significantly younger and with significantly lower body weight than BAT negative subjects. CONCLUSIONS: Whole body hybrid PET/MRI allowed for the identification of BAT, with a low prevalence, comparable to previous retrospective PET/CT studies realised in the absence of a cooling protocol. The main advantages of the PET/MRI hybrid technique, as compared with PET/CT, includes a lower radiation burden, and the possibility to combine a multiparameter fat characterization by dedicated MRI sequences. Hybrid PET/MRI might represent the ideal tool for BAT evaluation.


Assuntos
Tecido Adiposo Marrom/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Tecido Adiposo Marrom/anatomia & histologia , Adulto , Idoso , Temperatura Baixa , Feminino , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Incidência , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/metabolismo , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Suíça/epidemiologia , Termogênese , Distribuição Tecidual , Tomografia Computadorizada por Raios X , Imagem Corporal Total
14.
Semin Nucl Med ; 45(4): 304-21, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26050658

RESUMO

Breast cancer is an international public health concern in which an optimal treatment plan requires a precise staging. Both MRI and PET imaging techniques have made significant progress in the last decades with constant improvements that made both modalities clinically relevant in several stages of breast cancer management and follow-up. On one hand, specific breast MRI permits high diagnostic accuracy for local tumor staging, and whole-body MRI can also be of great use in distant staging, eventually accompanied by organ-specific MRI sequences. Moreover, many different MRI sequences can be performed, including functional MRI, letting us foresee important improvements in breast cancer characterization in the future. On the contrary, (18)F-FDG-PET has a high diagnostic performance for the detection of distant metastases, and several other tracers currently under development may profoundly affect breast cancer management in the future with better determination of different types of breast cancers allowing personalized treatments. As a consequence PET/MR is a promising emerging technology, and it is foreseeable that in cases where both PET and MRI data are needed, a hybrid acquisition is justified when available. However, at this stage of deployment of such hybrid scanners in a clinical setting, more data are needed to demonstrate their added value beyond just patient comfort of having to undergo a single examination instead of two, and the higher confidence of diagnostic interpretation of these co-registered images. Optimized imaging protocols are still being developed and are prone to provide more efficient hybrid protocols with a potential improvement in diagnostic accuracy. More convincing studies with larger number of patients as well as cost-effectiveness studies are needed. This article provides insights into the current state-of-the-art of PET/MR in patients with breast cancer and gives an outlook on future developments of both imaging techniques and potential applications in the future.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/terapia , Humanos
15.
Eur J Nucl Med Mol Imaging ; 42(7): 1133-43, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25893383

RESUMO

PURPOSE: In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. METHODS: This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. RESULTS: The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. CONCLUSION: This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations.


Assuntos
Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Eletroencefalografia/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Adolescente , Adulto , Criança , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/instrumentação , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Período Pré-Operatório
16.
Clin Nucl Med ; 40(4): 355-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25674869

RESUMO

Biodistribution and dosimetric aspects are important issues in the preparation realization of radionuclide therapies and thus play an emerging role in radioembolization of liver malignancies. Biodistribution assessment of liver selective internal radiotherapy (SIRT) has been shown feasible using PET/CT PET/magnetic resonance (MR). Whereas prospective dosimetry using 99mTc macroaggregated albumin SPECT/CT is discussed controversially, retrospective 90Y PET/CT has been shown feasible for dosimetry of SIRT in recent studies. Considering the advantages of PET/MR with regard to lesion detection radiation dose reduction compared to PET/CT, especially when repeated scanning is intended, we investigated the use of PET/MR for dosimetry of liver SIRT.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/administração & dosagem , Dosagem Radioterapêutica , Radioisótopos de Ítrio/administração & dosagem , Idoso , Carcinoma Hepatocelular/terapia , Embolização Terapêutica , Feminino , Humanos , Neoplasias Hepáticas/terapia , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/uso terapêutico , Distribuição Tecidual , Radioisótopos de Ítrio/farmacocinética , Radioisótopos de Ítrio/uso terapêutico
17.
J Neurointerv Surg ; 7(12): 913-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25280571

RESUMO

BACKGROUND: Flow diverter stents (FDS) have been effectively used for the endovascular treatment of sidewall intracranial aneurysms (IAs). Unlike standard endovascular treatments used to exclude directly the aneurysm bulge from the parent vessel, FDS induce reduction in the intra-aneurysmal flow and promote progressive and stable thrombosis therein. The advent of FDS has therefore increased the need for understanding of IA hemodynamics. METHODS: We proposed the use of the most recently evolved four-dimensional (4D) flow MRI technique to evaluate qualitatively and quantitatively post-FDS flow modification in 10 patients. We report intra-aneurysmal velocity measurements and the influence of metal artifacts induced by the stent. RESULTS: An index was defined to quantitatively measure flow changes-namely, the proportional velocity reduction ratio (PVRR)-with ranges from 34.6% to 71.1%. Furthermore, we could compare streamlines characterizing the post-stent flow patterns in five patients in whom the intra-aneurysmal velocity was beyond the visualization threshold of 7.69 cm/s. CONCLUSIONS: Despite metal artifacts and the low velocities involved, 4D flow MRI could be of interest to measure qualitatively and quantitatively flow changes in stented aneurysms. However, further enhancements are required together with further validation work before it can be considered for clinical use.


Assuntos
Velocidade do Fluxo Sanguíneo , Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/cirurgia , Imageamento por Ressonância Magnética/métodos , Stents , Velocidade do Fluxo Sanguíneo/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino
18.
IEEE Trans Med Imaging ; 34(1): 306-16, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25216480

RESUMO

Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, 10 short-axis slices were acquired across the entire heart using a multiple shifted trigger delay (TD) strategy under free breathing conditions. Interscan motion was first corrected automatically using a nonrigid registration method. Then, two post-processing schemes were optimized and compared: an algorithm based on principal component analysis (PCA) filtering and temporal maximum intensity projection (TMIP), and an algorithm that uses the wavelet-based image fusion (WIF) method. The two methods were applied to the registered diffusion-weighted (DW) images to cope with intrascan motion-induced signal loss. The tensor fields were finally calculated, from which fractional anisotropy (FA), mean diffusivity (MD), and 3-D fiber tracts were derived and compared. The results show that the comparison of the FA values (FA(PCATMIP) = 0.45 ±0.10, FA(WIF) = 0.42 ±0.05, P=0.06) showed no significant difference, while the MD values ( MD(PCATMIP)=0.83 ±0.12×10(-3) mm (2)/s, MD(WIF)=0.74±0.05×10(-3) mm (2)/s, P=0.028) were significantly different. Improved helix angle variations through the myocardium wall reflecting the rotation characteristic of cardiac fibers were observed with WIF. This study demonstrates that the combination of multiple shifted TD acquisitions and dedicated post-processing makes it feasible to retrieve in vivo cardiac tractographies from free-breathing DTI acquisitions. The substantial improvements were observed using the WIF method instead of the previously published PCATMIP technique.


Assuntos
Imagem de Tensor de Difusão/métodos , Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Ondaletas
19.
Eur J Nucl Med Mol Imaging ; 41(3): 462-75, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24108458

RESUMO

PURPOSE: Our objectives were to assess the quality of PET images and coregistered anatomic images obtained with PET/MR, to evaluate the detection of focal uptake and SUV, and to compare these findings with those of PET/CT in patients with head and neck tumours. METHODS: The study group comprised 32 consecutive patients with malignant head and neck tumours who underwent whole-body (18)F-FDG PET/MR and PET/CT. PET images were reconstructed using the attenuation correction sequence for PET/MR and CT for PET/CT. Two experienced observers evaluated the anonymized data. They evaluated image and fusion quality, lesion conspicuity, anatomic location, number and size of categorized (benign versus assumed malignant) lesions with focal uptake. Region of interest (ROI) analysis was performed to determine SUVs of lesions and organs for both modalities. Statistical analysis considered data clustering due to multiple lesions per patient. RESULTS: PET/MR coregistration and image fusion was feasible in all patients. The analysis included 66 malignant lesions (tumours, metastatic lymph nodes and distant metastases), 136 benign lesions and 470 organ ROIs. There was no statistically significant difference between PET/MR and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUVmean and SUVmax measured on PET/MR and PET/CT for malignant lesions, benign lesions and organs (ρ = 0.787 to 0.877, p < 0.001). SUVmean and SUVmax measured on PET/MR were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p < 0.05). The main factor affecting the difference between SUVs in malignant lesions was tumour size (p < 0.01). CONCLUSION: In patients with head and neck tumours, PET/MR showed equivalent performance to PET/CT in terms of qualitative results. Comparison of SUVs revealed an excellent correlation for measurements on both modalities, but underestimation of SUVs measured on PET/MR as compared to PET/CT.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Carcinoma de Células Escamosas/diagnóstico , Feminino , Fluordesoxiglucose F18/farmacocinética , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética
20.
IEEE Trans Med Imaging ; 32(10): 1928-38, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23797241

RESUMO

The use of diffusion tensor imaging (DTI) for studying the human heart in vivo is very challenging due to cardiac motion. This paper assesses the effects of cardiac motion on the human myocardial fiber architecture. To this end, a model for analyzing the effects of cardiac motion on signal intensity is presented. A Monte-Carlo simulation based on polarized light imaging data is then performed to calculate the diffusion signals obtained by the displacement of water molecules, which generate diffusion weighted (DW) images. Rician noise and in vivo motion data obtained from DENSE acquisition are added to the simulated cardiac DW images to produce motion-induced datasets. An algorithm based on principal components analysis filtering and temporal maximum intensity projection (PCATMIP) is used to compensate for motion-induced signal loss. Diffusion tensor parameters derived from motion-reduced DW images are compared to those derived from the original simulated DW images. Finally, to assess cardiac motion effects on in vivo fiber architecture, in vivo cardiac DTI data processed by PCATMIP are compared to those obtained from one trigger delay (TD) or one single phase acquisition. The results showed that cardiac motion produced overestimated fractional anisotropy and mean diffusivity as well as a narrower range of fiber angles. The combined use of shifted TD acquisitions and postprocessing based on image registration and PCATMIP effectively improved the quality of in vivo DW images and subsequently, the measurement accuracy of fiber architecture properties. This suggests new solutions to the problems associated with obtaining in vivo human myocardial fiber architecture properties in clinical conditions.


Assuntos
Coração/fisiologia , Modelos Cardiovasculares , Movimento/fisiologia , Miocárdio/citologia , Miofibrilas/fisiologia , Adulto , Simulação por Computador , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...